Evaluation of elevated prosthetic aortic jet velocity
Prosthetic and repaired valvesAdvanced
Text of this figure
- Evaluation of elevated prosthetic aortic jet velocity
- Prosthetic aortic jet velocity >3 m/s
- Early peak
- AT <100 ms
- AT/ET <0.37
- Late peak
- AT >100 ms
- AT/ET >0.37
- ≥0.30
- 0.29–0.25
- <0.25
- Normal AVR§
- Possible stenosis*§
- Stenosis*§
- Indexed EOA (cm²/m²):
- >0.85: High-flow state
- <0.85: Patient–prosthesis mismatch
- Consider:
- • Valve stenosis with small LVOT
- • Improper position of LVOT PW Doppler
- • Underestimation of jet Doppler velocity
- Consider:
- • Valvular stenosis including
- thrombosis
- • Subvalvular stenosis
- Jet contour
- DVI
- * Valve stenosis is further substantiated by EOA compared to respective reference values of similar valve type and size.
- § Assessment of mechanical valve motion: fluoroscopy & CT > TEE; etiology of valve stenosis: CT angiography & TEE > CMR.
- Source: Guidelines for the Evaluation of Prosthetic Valve Function With Cardiovascular Imaging: A Report From the American Society of Echocardiography Developed in Collaboration With the
- Society for Cardiovascular Magnetic Resonance and the Society of Cardiovascular Computed Tomography (2024), Figure 13.
- Please read the full document from the ASE.
Redrawn as a flowchart from the published document named in the figure. Read the full document for context and the figures' complete notes.