Prosthetic and repaired valves · Pathway
Advanced content
This pathway is classified as Advanced and is shown here because you opened it directly. Your study inputs are unaffected.
BSA — m²
After transcatheter edge-to-edge mitral repair: residual MR and inflow gradient
AdvancedVersion 2026.10.1
Residual MR from at least two concordant parameters (Table 7, post-intervention document), then the mean inflow gradient with heart rate and the residual valve area. PISA EROA and PHT MVA are not used after repair.
Read more:ASE 2019 · Regurgitation after percutaneous repair/replacementASE 2026 · Intraprocedural M-TEER imaging
Quick reference:↑ Mitral regurgitation
Applicability
- Residual MR and inflow gradient after transcatheter edge-to-edge mitral repair. All parameters have limitations; an integrated approach weighing the strength of each measurement is required.
- A gradient alone is interpreted with the heart rate and the residual MR, since residual MR contributes to the Doppler gradient.
- PI-2019 Table 7Do at least two concordant parameters indicate mild, moderate or severe residual MR?mL%Residual MR is graded from an integrated, multiparametric assessment: at least two usable parameters are needed; a single parameter does not grade it.
PISA-derived EROA is not recommended after edge-to-edge repair and is not accepted as an input.