BSA — m²

Prosthetic valve regurgitation and paravalvular leak

Advanced
Version 2026.10.1

Mechanism and location, then severity of prosthetic aortic regurgitation by counting specific mild and severe criteria and refining with quantitative parameters (Figure 16). Other positions are routed to guidance, not to a native pathway.

Applicability
  • Prosthetic aortic valve regurgitation (surgical or transcatheter, central or paravalvular). Good-quality imaging and complete data acquisition are assumed; with poor imaging or discordant parameters the result is indeterminate and TEE or CMR is considered.
  • Mitral, tricuspid and pulmonary prostheses are not graded here: TTE detection is limited and TEE is frequently needed.
  1. Next
    Which valve position is the prosthesis in?
    Prosthesis position is required.